Model |
7721 |
CO2 Range |
0~9999 ppm (2001~9999 ppm out of scale range) |
CO2 Resolution |
1 ppm |
CO2 Accuracy |
±50 ppm ±5% of reading (0~2000 ppm), other range are not specified |
CO2 Response Time |
<30 Seconds (90% step change) |
CO2 Warm-up Time |
30 Seconds |
Air Temperature Range |
-10~60℃, 14~140℉ |
Air Temperature Resolution |
0.1℃, 0.1℉ |
Air Temperature Accuracy |
±0.6℃, ±0.9℉ |
Air Temperature Response Time |
<2 mins (90% step change) |
LCD Size |
65(L) * 50(W) mm |
Meter Size |
130(L) * 85(W) * 60(H) mm |
Operating Temperature |
0~50℃ |
Operating RH% |
0~95% RH (avoid condensation) |
Storage Temperature |
-20~50℃ |
Storage RH% |
0~90% RH (avoid condensation) |
Power Supply |
12V DC Adaptor |
Battery life |
<50 mA (average), <310 mA (peak) |
Weight |
~200g |
Standard Package |
Meter, Manual, Paper Box, 12V USA Type Adaptor
|